Home > Products > Laboratory Instrument > Analyzer Machine > Laboratory Medical Fully-auto Biochemistry Analyzer

Laboratory Medical Fully-auto Biochemistry Analyzer

Basic Info

Model No.JT-DS161

BrandOEM

Additional Info

Packaging1pc/box

Productivity1000

TransportationOcean,Land,Air

Place of OriginChina

Supply AbilityGOOD

PortShanghai,Ningbo

Payment TypeL/C,T/T,D/P,Paypal

IncotermFOB,CFR,CIF

Product Description

Laboratory Medical Fully-auto Biochemistry Analyzer



Product name: Fully-auto biochemistry analyzer

Item No.: JT-DS161

Application:

Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

Fully-auto Biochemistry Analyzer



Technical Specifications:

Model

DS161

Analytical System

Fully automatic, Random Access

Method

End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc

Assay Item

30 assay

Throughput

1 Reagent

160 tests/hr

2 Reagent

100 tests/hr

Test Menu

T.BILI         r-GT/GGT    CHO    Ca      APOB-1/B   CHE

D.BILI        ALP/AKP     TG      CL      APOB       CREA

TP           UREA        CK      P       CK-MB      Mg

ALB          CREA        LDH    C        ASO        AFU

Lactic Acid    ALT/GPT      UA    α-HBDH  CO2        FMN

LP(a)         AST/GOT     GLU   AMY      LDL-C      HDL-C

CHE          LA           TBA    ADA      HS-CRP    PA

Fe            Cu           Zn     C3       C4          IgG

IgM           IgA           and drug, toxicity,etc.

Sample Position

30

Including standard, control and STAT; either serum cup or primary tube available

Sample Volume

1~100ul, 0.1ul/step

Reagent Position

40

Reagent Volume

R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step

Reagent/Sample Probe

With liquid level sensor, collision sensor, Teflon coating and automatic washing station

Reaction Time

0~999 seconds

Cuvette

High quality uv-transmitted plastic cuvette.

Cuvette Washing

5 channels automatic washing system for reaction cuvettes

Probe and Mixer Washing

Independent washing station for each sample/reagent probe and mixer

Alarm

Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc)

Calibration

Linear, Non-linear, Multi standard, K factor

Sample Dilution/Retest

Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function

Wavelength

340-810nm

Light Source

Halogen lamp

Absorbance Resolution

0.0001A

Absorbance Accuracy

±0.0003A(0-2.5A)

Repeatability

±2%

Quality Control

Levy jennings quality control program at 3 levels

Barcode

Optional

Printer

Multiple report formats available

System

Windows XP; Windows 7

Power Supply

220V or 110V, 50~60Hz

Dimension

65×53×52(cm)

Weight

45kg

 

Features:

 

Random access fully automatic biochemistry analyzer

New concept and more friendly software

Automatic washing station for both sample and reagent probe

Liquid level detection and collision protection for both sample and reagent probe

Reliable cooling system for reagent chamber

Powerful reaction cuvette washing system

barcode scanner (optional)

Lower waste and pro-environment

 

Structure:

1. Optical System

Light source: Halogen-tungsten lamp, 2000hours working life about

Wavelength: 340nm-810nm

Linear range:0~3ABS

2. Sample System

a) Sample tray: 30 sample position, available to use serum cup or blood tube

b) Sample volume:1~100ul, programmed by 0.1ul step

c) Sample probe: Liquid level detection and collision protection automatically

d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%

e) Automatic sample dilution

3. Reagent System

a) Reagent tray: 40 positions for single &dual Reagents.

b) Refrigeration: Refrigerated reagent

c) Compartment 24h Cooling system maintaining temperature 2~8°C

d) Reagent volume:1~400ul, programmed by 0.1ul step

e) Reagent probe: Liquid level detection and collision protection automatically

f) Pre-heating function.

g) Real-time monitoring of reagent volume and auto alarm

h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System

a) Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt

b) Back-Dividing-Light technology

c) Min Reaction volume: 200ul

d) Reaction Temperature:37°C+0.1°C

e) Mixing system: Independent mixing probe

f) Automatic washing cuvettes

5. Washing System

a) Automatic cleaning Sample/mixer probe 

b) Five channels washing station for each cuvette

c) Automatic record and deduct cuvette blank value

6. Operation Unit

Operation system: Windows XP, WIN 7, WIN 8

Interface: RS-232

7. Working Conditions

a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)

b) Power consumption: ≤1200VA

c) Temperature:15~30°C

d) Humidity: ≤85%

e) Water consumption: 4L/h

Advantage of Our Company

Product Range:
Diagnosis Equipment , Medical Bed & Table , Surgical Equipment

1. Professional medical products manufacture for more than 10 years

2. High quality with competitive price

3. Independent Design and Outstanding Sales Team

4. Large Supply Ability

5. Excellent after-Sales service


Product Categories : Laboratory Instrument > Analyzer Machine

Product Images

  • Laboratory Medical Fully-auto Biochemistry Analyzer
Email to this supplier
  • Ms. Frances Xu
  • Your message must be between 20-8000 characters

Related Productslist

Home

Phone

Skype

Inquiry